15.36kWh 12kW APOLLO C Stackable All-in-One ESS

15.36kWh 12kW APOLLO C Stackable All-in-One ESS

Model

The APOLLO C combines a twelve kilowatt inverter with a fifteen point three six kilowatt hour LiFePO4 pack and delivers 110V/230V split-phase output from a single compact unit. One cabinet, two voltages: the APOLLO C supplies 110V/230V split-phase output for appliances and sub-panels from its twelve kilowatt inverter and fifteen point three six kilowatt hour bank.

View full details
15.36kWh 12kW APOLLO C Stackable All-in-One ESS — Technical Specifications
MODELSW-C-51.2-300-12KW
Inverter
Rated Power12kW
AC Rated Voltage230Vac
Rated Frequency60Hz
Efficiency≥98%
Transfer Time10ms
WaveformPure Sine Wave
Battery Overvoltage58.4V
Battery Undervoltage Alarm45V
Constant Voltage Charge58.4V
Float Voltage56V
Max. Charging Current160A
Communication InterfaceUSB(Inverter)/RS485(BMS)
Dimension70×26×51cm
AC Input
Nominal Voltage230Vac
Voltage Range90-280Vac
Rated Frequency50/60Hz
Frequency Range40-70Hz
Rated Current60A
Max. AC Current160A
PV Input
Max. Voltage500V
Optimum Voltage300-400V
Voltage Range80V-500Vdc
Max. Power27A+27A/15000W
Battery
Rated Capacity15360Wh(300Ah)
Nominal Voltage51.2V
Discharge Voltage Range43.2V-58.4V
Standard Charing Current100A
Max. Charging Current200A
Max. Discharging Current200A
Depth of Discharge95%
Communication InterfaceCAN/RS485
Cycle Life≥8000, 25±2°C, 0.5C, EOL80%
Working Temperature RangeCharge: 0°C-50°C; Discharge: -20°C-60°C
Storage Temperature-20°C-60°C
Dimension70×26×51cm

Features

  • Split-phase for shops The twelve kilowatt stage runs 110V/230V split-phase, so a workshop, stall or small office draws from one cabinet without a separate step-up transformer.
  • Tool-grade wave A true sine output starts motors cleanly; pumps, compressors and POS all see stable voltage through a switchover.
  • Add a block A second twelve kilowatt cabinet bolts onto the same bus to raise the fifteen point three six kilowatt hour total; the BMS treats both as one bank.
  • Bank protection The BMS watches every cell in the fifteen point three six kilowatt hour pack, isolating a weak cell before it drags the rest down.
  • Built to cycle The LiFePO4 chemistry is rated for daily charge and discharge, holding capacity through years of commercial use.
  • Mixed source Panels, grid or a genset all feed the one MPPT inlet, so the fifteen point three six kilowatt hour store tops up from whatever is on hand.

Applications

  • Evening solar self-use: Rooftop generation is captured by day and released after sunset, so more of the fifteen point three six kilowatt hour store serves the home itself.
  • Peak-period bill cut: It stores cheap midday power and gives it back when prices climb, smoothing the peak-demand charges on the account.
  • Workshop & tools: Power tools and machinery pull a steady two hundred thirty volt wave from the twelve kilowatt stage, with no flicker on motor start.
  • Small business: Tills, routers and lighting stay up on the twelve kilowatt supply, so a shop keeps trading through a blackout.
  • Market stall: A till, scale and lighting run from one quiet cabinet, so a vendor trades anywhere the sun or battery reaches.
  • Off-grid cabin: Off the grid, the fifteen point three six kilowatt hour store carries a cabin or kiosk day and night from panels or a genset.

Energy Management & System Architecture

The APOLLO C keeps one cabinet body and delivers 110V/230V split-phase output, so the twelve kilowatt stage and fifteen point three six kilowatt hour bank match the destination wiring. One cabinet, two voltages: the fifteen point three six kilowatt hour twelve kilowatt cabinet outputs 110V/230V split-phase, serving home, shop and small plant.

On-grid it self-consumes and banks surplus; islanded the twelve kilowatt inverter carries the load while the BMS fences off weak cells. The BMS treats solar, grid and generator as one source and protects the fifteen point three six kilowatt hour pack through constant use on the local line.

Grid, Backup & System Integration

When mains fails the fifteen point three six kilowatt hour store carries the site with no manual switch, the twelve kilowatt stage holding the load until power returns. Blackout response is measured in moments: the twelve kilowatt stage pulls the fifteen point three six kilowatt hour bank online before appliances notice, on the local split-phase standard.

Another cabinet is later added to the same bus, so the fifteen point three six kilowatt hour total rises without fresh wiring or a second controller. The BMS merges every stacked block into one virtual battery, so reserve grows with the physical stack and the feed stays unified.

Warranty

We provide a 5-year warranty on the battery and a 2-year warranty on the inverter of this product. If you experience any quality issues within the warranty period, please contact us and we will arrange a replacement or repair promptly.

Frequently Asked Questions

Is it truly split-phase?

Yes. The inverter is built for the 110V/230V split-phase standard from the factory.

Will it lower my bill?

Yes. It banks midday solar and discharges through the evening peak.

What runs in a blackout?

The twelve kilowatt stage keeps essentials alive for hours on the split-phase output.

Indoor safe?

Yes. The BMS isolates faults; keep air moving.

Expert Support

Our team of solar energy experts is ready to help you find the perfect solution for your needs.

Fast Response

We typically respond to all inquiries within 24 hours during business days.

Custom Solutions

Every project is unique. Let us design a solar solution tailored to your specific requirements.