Skip to product information
1 of 1

SunWell Energy

10.24kWh 6kW ARES Mobile All-in-One ESS

10.24kWh 6kW ARES Mobile All-in-One ESS

Model

Rugged and rollable, the ARES packs a six kilowatt inverter and a ten point two four kilowatt hour LiFePO4 cell set on a wheeled frame ready for two hundred thirty volt loads anywhere. Off-grid in a cart: ARES carries ten point two four kilowatt hour of storage and six kilowatt of inverter, rolling out instant two hundred thirty volt backup for a home or worksite.

View full details
10.24kWh 6kW ARES Mobile All-in-One ESS — Technical Specifications
MODELSW-6KW-10KWH
Inverter
Rated Power6KW
AC Rated Voltage230Vac
Rated Frequency50/60Hz
Efficiency≥98%
Transfer Time10ms
WaveformPure Sine Wave
Battery Overvoltage58.4V
Battery Undervoltage Alarm45V
Constant Voltage Charge58.4V
Float Voltage56V
Protection Voltage43.2V
Max. Charging Current100A
Communication InterfaceUSB(Inverter)/RS485(BMS)
AC Input
Nominal Voltage230Vac
Voltage Range90-280Vac
Rated Frequency50Hz
Frequency Range40-70Hz
Rated Current60A
Max. AC Current120A
PV Input
Max. Voltage500V
Optimum Voltage300V-400V
Voltage Range80V-500V
Max. Power27A/9000W
Battery
Rated Capacity10240Wh(200Ah)
Nominal Voltage51.2V
Discharge Voltage Range43.2V-58.4V
Standard Charing Current50A
Max. Charging Current100A
Max. Discharging Current100A
Depth of Discharge95%
Communication InterfaceCAN/RS485
Cycle Life≥8000 25°C±2°C, 0.5C, EOL80%
Working Temperature RangeCharge: 0°C-50°C; Discharge: -20°C-60°C
Storage Temperature-20°C-60°C
Dimension48×84×30cm

Features

  • Wheels included Move the ten point two four kilowatt hour six kilowatt store between buildings. Roll it from the barn to the cabin without lifting a kilogram.
  • Live socket The six kilowatt inverter gives two hundred thirty volt the second it is connected. The site comes online as soon as the plug seats.
  • Transport pack A LiFePO4 ten point two four kilowatt hour cell set rated for motion. It is anchored and padded so vibration never loosens a connection.
  • Guarded move The BMS locks the six kilowatt stage during transport. No spark, no surge, just a dormant pack that wakes on plug-in.
  • Dual refill Panels or generator recharge the ten point two four kilowatt hour cells. Keep one in the sun and the other on a genset to double the turnaround.
  • Rough ready A sealed body suits a outdoor site. Dust, splash and grit stay outside the electronics bay.

Applications

  • Outdoor event: A stall or stage draws clean power from the cabinet, avoiding a long cable run back to the grid.
  • Market stall: Scales, a card reader and lamps draw from the single cabinet, letting a stall operate far from any outlet.
  • Small business: Tills, routers and lighting stay up on the six kilowatt supply, so a shop keeps trading through a blackout.
  • Whole-home backup: When the mains fails, the six kilowatt stage holds two hundred thirty volt so the home's essentials stay on without a hitch.
  • Off-grid cabin: Off the grid, the ten point two four kilowatt hour store carries a cabin or kiosk day and night from panels or a genset.
  • Cold storage: During an outage the ten point two four kilowatt hour bank keeps freezers and fridges cold, protecting perishable stock.

Energy Management & System Architecture

A rugged BMS reads knocks and temperature and feeds the six kilowatt inverter and the ten point two four kilowatt hour cells, so the cart stays safe in transit and in use. Inside the sealed cabine a six kilowatt inverter, MPPT and the ten point two four kilowatt hour LiFePO4 pack share a bus the BMS watches through motion and heat.

By day it banks PV and replays it after sunset at two hundred thirty volt; during a blackout the six kilowatt stage engages quickly and the BMS keeps each cell within bounds. Each day it turns sunlight into two hundred thirty volt and tops the bank; away from mains the six kilowatt output powers the site while the BMS guards every cell.

Grid, Backup & System Integration

The cart charges from panels or a genset through one inlet, so even with no sun the ten point two four kilowatt hour pack keeps filling while the BMS guards the cells. When mains fails the ten point two four kilowatt hour store carries the site with no switch, the six kilowatt stage holding two hundred thirty volt until power returns.

If the grid then fails, the six kilowatt stage hands two hundred thirty volt to the load with no pause. A second ARES can later roll up beside it, so the ten point two four kilowatt hour total grows without fresh wiring or a second controller.

Warranty

We provide a 5-year warranty on the battery and a 2-year warranty on the inverter of this product. If you experience any quality issues within the warranty period, please contact us and we will arrange a replacement or repair promptly.

Frequently Asked Questions

Can it charge from a generator?

Yes. The panel inlet doubles as a genset port.

Is the ten point two four kilowatt hour pack built for daily moving use?

It is made for exactly that — nightly charge, discharge and transport.

Expandable?

Roll a six kilowatt unit alongside; the BMS adopts it and lifts the ten point two four kilowatt hour total.

Safe to live with?

Yes. The cart is sealed and the BMS cuts faults at once; give it ventilation.

Expert Support

Our team of solar energy experts is ready to help you find the perfect solution for your needs.

Fast Response

We typically respond to all inquiries within 24 hours during business days.

Custom Solutions

Every project is unique. Let us design a solar solution tailored to your specific requirements.